CONVERTER FOR MONITORING STATION
SMET-256
USER MANUAL
Program version v1.07 smet256_en 04/11
®
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - SMET-256

CONVERTER FOR MONITORING STATION SMET-256 USER MANUAL Program version v1.07 smet256_en 04/11 ®

Page 2

8 SMET-256 SATEL - subscriber defined, but there is currently no communication between the converter and the subscriber. 4.5 "UNREGISTERED"

Page 3 - 2. CONVERTER DESCRIPTION

SATEL SMET-256 9 4.7 "CONFIGURATION" WINDOW "Network" tab Fig. 5. The "Network" tab, "Configuration" windo

Page 4 - 3. CONVERTER INSTALLATION

10 SMET-256 SATEL MAC control – select this field if the converter is to receive transmissions only from the devices with defined MAC numbers. It wi

Page 5 - 4. CONFIGURING THE CONVERTER

SATEL SMET-256 11 Time server (NTP) – available, if the “Time synchronization” box is checked. In this field, enter the IP address of the time server

Page 6 - 4.2 SMET-256 SOFT PROGRAM

12 SMET-256 SATEL "Reporting" tab Fig. 8. The "Reporting" tab, "Configuration" window in the web browser (the window av

Page 7 - UBSCRIBERS" TAB

SATEL SMET-256 13 during communication. The identical server key must be entered in the settings for monitoring the subscriber's device. By defa

Page 8 - 6 SMET-256 SATEL

14 SMET-256 SATEL Receiver No. [1-9] – the field is available, if the SurGuard (MLR2/MLR2E) format has been selected. Enter in it the number of receiv

Page 9 - SATEL SMET-256 7

SATEL SMET-256 15 HTTP port – in this field, enter the number of network port to be used for opening the web browser. Values from 1 to 65535 can be e

Page 10 - 4.6 „LOG EVENTS” TAB

16 SMET-256 SATEL Ping The parameters defined in this area will activate the function of ping command sending. Enabled – select the box to activate th

Page 11 - "Network" tab

SATEL SMET-256 17 • The IP address and port defined in the "Program settings" tab may be different from the IP address of the converter pr

Page 12 - "RTC" tab

SATEL's goal is to continually improve the quality of its products, which may lead to alterations in their technic

Page 13 - "RS port" tab

SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.pl

Page 14 - "Reporting" tab

SATEL SMET-256 1 The SMET-256 converter is a solution offered to firms engaged in the monitoring of security alarm systems. It receives events sent t

Page 15 - SATEL SMET-256 13

2 SMET-256 SATEL Explanations for Fig. 1: 1 – LED indicators: PWR – power indicator – ON when power supply is connected ST – status indicator: − ON –

Page 16 - 14 SMET-256 SATEL

SATEL SMET-256 3 4. CONFIGURING THE CONVERTER Note: The device is only designed for working in the local computer networks (LAN). It cannot be direc

Page 17 - "Advanced" tab

4 SMET-256 SATEL 4.2 SMET-256 SOFT PROGRAM 4.2.1 Configuration through RS-232 port Note: The converter default settings provide for operation in the

Page 18 - 16 SMET-256 SATEL

SATEL SMET-256 5 10 - failure indication icon. To see description of the failure hover the cursor over the icon. The grayed out icon means lack of f

Page 19 - 5. SPECIFICATIONS

6 SMET-256 SATEL Fig. 4. The „Subscribers” tab in web browser with some examples of subscriber definitions (the window available in SMET-256 Soft pro

Page 20

SATEL SMET-256 7 Note: Be careful when selecting parameters to be entered in the fields "Test period" and "Number of missing tests&qu