Satel CA10 plus - LCD keypad Programming and Installation Manual
- 15 -
The following priority levels are assigned by default (starting with the highest):
1. entry delay,
2. fire alarm,
3. burglary alarm,
4. armed (or silent armed)
5. fire alarm occurred,
6. burglary alarm occurred,
7. exit delay.
Reset Defaults
The function restores default parameters of keypad.
Test
The function enables keypad functioning correctness to be tested. Starting this function
restores default keypad parameters. To preserve your own parameters it is necessary
to write them into computer before testing, and after testing they should be again
programmed from the computer. Pressing key [
*
] after end of testing will restart keypad.
Computer supported programming
All keypad parameters (v3.00) can be programmed from the computer by means of the
DLOAD10
program working in the WINDOWS environment (version 1.00.03 and later).
The program serves also the previous versions of LCD keypads. Use the cable for
panel programming to connect the keypad to the computer RS-232 port. No
initialization is required - the keypad will automatically respond to DLOAD10
commands.
Vue de la page 16
1 2 ... 12 13 14 15 16 17 18 19

Commentaires sur ces manuels

Pas de commentaire

Wahl Masseurs manuels d'utilisation

À partir de 0-9

Cliquez sur un alphabet ci-dessous pour faire défiler la liste complète des modèles commençant par cette lettre

Modèles Type de document
4295
Instructions d'exploitation    Wahl 4295 massager, 2 pages