USER MANUAL CA-10
16
The text mode is signaled by * in the upper right corner of the display.
Numeric keys in text mode insert letters at the cursor position according to the
preceding table. Lowercase characters are entered by pressing a numeric key twice.
 keys enable the previous/next character selection.
In numeric mode key deletes the character before the cursor, and key switches
between insert/typeover modes.
An access code can have the following functions/authority levels:
1 - accessible all functions, except creating and deleting users,
2 - accessible arming and disarming, change of access code,
3 - accessible arming, while disarming is only possible when the system was
armed with the same access code,
4 - code trap: it arms and disarms the system, but disarming sends a DURESS
("disarmed under duress") message to the monitoring station,
5 - activates the MONO SWITCH output, its use is recorded in the event log, can
serve as a guard code,
6 - changes the state of BI SWITCH output,
7 - partial arming - the code arms the system, simultaneously bypassing a group of
zones (specified by the installer in service functions), otherwise the code
provides the same features as that with authority level 2,
8 - accessible arming and disarming, without possibility to change own access
code,
9 - accessible arming only,
0 - accessible alarm clearing only.
Note: The codes with authority level 5 and 6 may be used in the following manner:
1. To control single outputs by means of the user functions:
the code with authority level 5 enables the function 7 ([CODE][
*
][7]) i.e.
activates any output of the MONO switch type,
the code with authority level 6 enables the function 8 ([CODE][*][8]) i.e. changes
the state of any output of the BI switch type.
2. To control all the outputs of a particular type, which belong to the partition where
the given code was created:
the code with authority level 5 will activate the MONO switch type outputs
([CODE][#]),
the code with authority level 6 will change the state of the BI switch type outputs
([CODE][#]).
EXAMPLE: enter the user code [3546] with authority level 2; master user code [1234]
[1234] [
*
] - call the "user function" mode; it should be acknowledged by one short beep
and blinking of the LEDs:
[ALARM], [ARMED], [TROUBLE]
[2] - call the "User add" function, it should be acknowledged by two short beeps
[3546] [#] - enter the new code digits; their acceptance will be acknowledged by three
short beeps
[2] - assign authority to the code; the function will be quitted automatically which
will be confirmed by four short and one long beeps
User (code) erase [CODE][
*
][3]
This function is used for deleting the codes of existing users to revoke their right to use
the system. After entering the number of the user to be deleted, the panel waits for