12. 3EOL/NO – the zone supports a detector of NO type with three EOL resistors in the
circuit.
Sensitivity – depending on wiring type:
NO, NC, EOL, 2EOL/NC, 2EOL/NO, 3EOL/NC and 3EOL/NO – the time during which the
zone must be violated, so that it can be noted by the control panel.
Roller / Roller 2EOL – 2 parameters are to be programmed:
Pulses duration – the time period during which a specified number of pulses must
occur (P
ULSES COUNT
) for the zone to be violated. You can program the following
values: 30 s, 120 s, 240 s and 0. Having programmed the value 0 means that the
pulses will be counted the whole time when the zone is armed (the pulse counter will
only be reset at arming/disarming).
Pulses count – the number of pulses after which the zone will be violated. You can
program values from 1 to 8.
Vibration / Vibration 2EOL – 2 parameters are to be programmed:
Sensitivity – occurrence of a pulse whose duration is equal to or longer than the
defined time will cause violation of the zone. You can program values from the 3 ms
to 96 ms range (every 3 ms).
Pulses count – the number of pulses after which the zone will be violated. You can
program values from 0 to 7. If the value 0 is programmed, the pulses will not be
counted – only S
ENSITIVITY
will be taken into account.
In the keypad, depending on the wiring type, different functions are available to allow
programming the sensitivity related parameters. In the D
LOAD
X program, all
parameters can be programmed in the S
ENSITIVITY
field.
Fig. 5. Example of zone settings in the D
LOAD
X program.
Output – refers to the F
OLLOW OUTPUT
wiring type. Indicate the number of output whose
activation will violate the zone. The output can be a virtual one.
Max. violation time / Max. door opening time – exceeding the maximum time of
violation/door opening is recognized by the control panel as a detector failure/door failure.
If the value 0 is programmed, control of this time is disabled.