SATEL INTEGRA Plus 41
16...31 C
OUNTING
C1...16 – the counting zones will signal an alarm when the number of
violations counted during a specified time period exceeds the set value (see: section
C
OUNTERS
p. 45). Violations of the counting zones in armed mode can be signaled at the
9. DAY
A
LARM
, 12. S
ILENT ALARM
and 116. I
NTERNAL
S
IREN
outputs.
32. 24
H
F
IRE
33. 24
H
F
IRE
–
S
MOKE
34. 24
H
F
IRE
–
C
OMBUSTION
35. 24
H
F
IRE
–
W
ATER FLOW
(
FIRE
)
36. 24
H
F
IRE
–
H
EAT
37. 24
H
F
IRE
–
P
ULL STATION
38. 24
H
F
IRE
–
D
UCT
39. 24
H
F
IRE
–
F
LAME
The zone types from 32 to 39 cause a fire alarm. The names of zones and codes of events
from these zones are consistent with the Contact ID reporting format. The fire zones (except
for 24
H
F
IRE
–
B
UTTON
) can work with alarm verification.
40. 24
H
F
IRE SUPERVISORY
41. 24
H
L
OW WATER PRESSURE
42. 24
H
L
OW
CO2
43. 24
H
W
ATER VALVE DETECTOR
44. 24
H
L
OW WATER LEVEL
45. 24
H
P
UMP ACTIVATED
46. 24
H
P
UMP FAILURE
47. N
O ALARM ACTION
– may be used to control the outputs. Additional options (S
TORE TO
EVENT LOG
, N
O REPORTING
and S
TORE EVENT ONLY IF ARMED
) enable the zone to be used for
other applications e.g. supervising the keybox.
48. 24
H AUXILIARY
–
P
ROTECTION LOOP
49. 24
H AUXILIARY
–
G
AS DETECTOR
50. 24
H AUXILIARY
–
R
EFRIGERATION
51. 24
H AUXILIARY
–
L
OSS OF HEAT
52. 24
H AUXILIARY
–
W
ATER LEAKAGE
53. 24
H AUXILIARY
–
F
OIL BREAK
54. 24
H AUXILIARY
–
L
OW BOTTLED GAS LEVEL
55. 24
H AUXILIARY
–
H
IGH TEMPERATURE
56. 24
H AUXILIARY
–
L
OW TEMPERATURE
57. T
ECHNICAL
–
D
OOR OPEN
– zone intended for supervising the status of the door defined as
D
EPENDENT DOOR
in the module executing the access control functions (partition keypad,
code lock, readers expander).
58. T
ECHNICAL
–
D
OOR BUTTON
– zone violation will result in opening the door controlled by
the module executing the access control functions (partition keypad, code lock, readers
expander).
59. T
ECHNICAL
–
AC
LOSS
– intended for control of devices working together with the alarm
control panel e.g. additional power supply units. Violation of the zone will cause a trouble
condition.
60. T
ECHNICAL
–
BATTERY
LOW
– intended for control of the batteries of additional power
supply units working in conjunction with the control panel. Violation of the zone will cause
a trouble condition.