54 Programming SATEL
Output forcing T1 – you can indicate the output which will force the first temperature
threshold. If the output is active, the first temperature threshold will be active. When the
output is inactive, the control timers will decide which temperature threshold is active.
The output 256 cannot be indicated as the forcing one.
Timers controlling T1/T2 – you can indicate the timers which will control the temperature
threshold. When the control timer is ON, the second temperature threshold will be active
(unless the forcing output is active).
The user can edit the parameters of control timers using the T
IMERS
user function
available in the C
HANGE OPTIONS
submenu.
4.8 Output groups
Fig. 7. Window "Output groups" in the D
LOAD
X program.
The outputs of MONO
SWITCH
, BI
SWITCH
, R
EMOTE SWITCH
,
S
HUTTER UP
and S
HUTTER DOWN
type can be grouped by the function performed by them. Each group may be given a name.
The output groups can be defined:
using the keypad, in the service mode, by means of the O
UTPUT GROUPS
function;
using the D
LOAD
X program, in the "Output groups" window (to open the window, press the
"Output groups" button in the "Outputs" window).
If all outputs are assigned to one group of outptuts, the keypad will not display the list
of output groups upon starting the R
EMOTE CONTROL
user function, but it will
immediately display the list of outputs which can be controlled.
The output can be assigned to a few groups.
If the output is not assigned to any group, it cannot be controlled from the keypad.