70 Programming SATEL
transmission format required by the monitoring station;
identifiers assigned to the alarm system;
list of event codes (not applicable to Contact ID and SIA formats).
9.1 Reporting parameters and options
See also section T
ELEPHONE OPTIONS
p. 56.
Shown in square brackets are the names used in keypads.
No module restart reports [No rest. mon.] – when this option is enabled and the Contact ID
or SIA format is used for reporting, no event codes referring to module restarts will be sent
to the monitoring station.
9.1.1 Selection of the monitoring station
Station 1 or Station 2 – the control panel will make an attempt to send the event code to
station 1 and, if unsuccessful, to station 2.
Station 1 only – the event codes are only sent to station 1.
Station 2 only – the event codes are only sent to station 2.
Station 1 and 2 – the event codes are sent to both stations. For most formats, it is possible
then to define which events will be sent to the given station (see: E
VENTS ASSIGNMENT
).
9.1.2 Advanced options
Long kiss-off signal – with this option enabled, the control panel will accept a long kiss-off
(acknowledgment) signal for receiving events in case of Ademco Express and Contact ID
formats. Enable this option in the event of telephone reporting if the monitoring station
acknowledges receiving events in a non-standard way (the kiss-off signal is longer than
800 ms).
Longer waiting for initial handshake – with this option enabled, the control panel will wait
longer for handshake from the monitoring station in case of sending events in the Ademco
Express, Contact ID or SIA format. Enable this option in the event of telephone reporting, if
the monitoring station sends a non-standard initial handshake.
Identifier confirmation required – the option refers to the SIA format. If it is enabled, the
control panel waits for acknowledgement by the monitoring station of receiving the
identifier with which the data were sent. The option refers to the telephone reporting.
6-character identifier – the option refers to the SIA format. If it is enabled, events will be
sent with a 6-character identifier. It consists of 2 parts: 2-character prefix and 4-character
identifier.
Send event source name – the option refers to the SIA format. If it is enabled, the name of
event source (zone, user, etc.) will also be sent along with the event code.
Send event partition name – the option refers to the SIA format. If it is enabled, the name of
partition where the event occurred will also be sent along with the event code.
Each data block conf. required – the option refers to the SIA format. If it is enabled, the
control panel waits for acknowledgement by the monitoring station of receiving each data
block. The option refers to the telephone reporting.
9.1.3 Monitoring station 1 / Monitoring station 2
Telephone number [Tel. 1 number] – basic telephone number of the monitoring station.
Backup telephone number [Tel. 2 number] – a backup telephone number of the monitoring
station. The control panel will make an attempt of reporting to that telephone number, if the
attempt of reporting to the basic telephone number fails.